Skip to main content
Home page
Site map
Search
Contact Us
Testing and Validation
Wash Checks

Monitoring the cleaning of instruments is vital, because if an instrument isn’t clean it can’t be sterilised. Wash checks should clearly identify problems within the cleaning process.

Key Points:

• Monitoring of wash process in Washer Disinfectors

• Clear indication of pass or fail

• For use within HTM 01-05 Quarterly Cleaning schedule

 

Sizes: Bag of 50 wash checks

HTM01-05 Compliance:

• 13.3

Downloads:
There are no downloads for this product
Wash Check Holder

Specifically designed to hold Dentisan Wash Checks.

 

Key Points:

• Re-usable

• Interchangeable between washer disinfector and ultrasonic bath

• For use within HTM 01-05 Quarterly Cleaning schedule

 

Sizes: Pack of 1 holder

HTM01-05 Compliance:

• 13.3

Downloads:
There are no downloads for this product
Protein Residue Test

Weekly protein test with the ability to detect residual proteins left on the surfaces of hard to clean dental and surgical instruments. For use with washer disinfectors, ultrasonic baths and even manual cleaning.

Key Points:

• Detects as low as 1microgram of protein

• Colour change gives instant results (within 10 seconds)

• 3 inch swab

 

Sizes: 2 kits: each kit contains 25 test vials and 25 swabs

HTM01-05 Compliance:

• 13.3

Downloads:
There are no downloads for this product
Bowie Dick Green Card

Bowie Dick is a daily test that checks the steam penetration in an autoclave. This card is the smallest and most cost effective on the market, yet delivers accurate results that are easy to interpret.

 

Key Points:

• Clear, accurate colour change

• Easy to interpret and record

• Non toxic

• Single use

• 3.5 minutes at 134°C

 

Sizes: Case of 120 test cards

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Bowie Dick Test Card Starter Kit

Complete Bowie Dick kit containing test cards and specially designed holder.

Key Points:

• Single use cards

• Autoclavable holder

 

Sizes: Kit contains 1 holder and 31 test cards

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Green card T Table Top BD Test

Air removal and steam penetration test designed to ensure that a successful vacuum has been achieved so the steam is able to penetrate an internal lumin.

 

Key Points:

• Clear, accurate colour change

• Easy to interpret and record

• Non toxic

• Single use

• 3.5 minutes at 134°C

 

Sizes: Bags of 15 test cards

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Helix

Daily steam penetration test for autoclaves. The Heli-check hollow load Process Challenge Device is a reusable device with disposable chemical indicator strips.

 

Key Points:

• Indicator change from pink to black demonstrates correct steam sterilisation conditions

• Provides permanent record of compliance

• 3.5 minutes at 134°C

 

Sizes: Kit of 250 indicator strips and 1 Helix device

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Class 4 Indicator

To ensure correct sterilization conditions have reached packaged instruments. Indicator strips monitor one or more sterilisation processes for the purpose of detecting sterilisation failures in packaging, loading or steriliser function.

 

Key Points:

• Steam, rather than heat alone is required to initiate colour change

• Provides permanent record of compliance

• 2.5 minutes at 134°C

 

Sizes: Bag of 250 indicators

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Class 5 Indicator

To ensure correct sterilization conditions have reached packaged instruments. Indicator strips monitor one or more sterilisation processes for the purpose of detecting sterilisation failures in packaging, loading or steriliser function.

Key Points:

• Steam, rather than heat alone is required to initiate colour change

• Provides permanent record of compliance

• Dual temperature strips 121°C or 134°C

 

Sizes: Bag of 250 indicators

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Class 6 Indicator

To ensure correct sterilization conditions have reached packaged instruments. Indicator strips monitor one or more sterilisation processes for the purpose of detecting sterilisation failures in packaging, loading or steriliser function.

 

Key Points:

• Steam, rather than heat alone is required to initiate colour change

• Provides permanent record of compliance

• 3.5 minutes at 134°C

 

Sizes: Bag of 250 indicators

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product
Class 6 Indicator with Adhesive

To ensure correct sterilization conditions have reached packaged instruments. Indicator strips monitor one or more sterilisation processes for the purpose of detecting sterilisation failures in packaging, loading or steriliser function.

Key Points:

• Steam, rather than heat alone is required to initiate colour change

• Adhesive backed to easily provide permanent record of compliance

• 3.5 minutes at 134°C

 

Sizes: Bag of 250 indicators

HTM01-05 Compliance:

• 12.5

Downloads:
There are no downloads for this product